Welcome To Lulink Electronics Technology Co., Ltd. Official Website!

Online Service

GYTS Outdoor Optical Cable

GYTS Outdoor Optical Cable
Number: GYTS
  • Product introduction

Application:                                                                    

l Laying method: Duct/Aerial

l Suitable for long-distance trunk and LAN communication.

l Fiber type: Single-mode/Multimode

l 

Characteristics

l The PSP is longitudinally applied over the cable core, which is filled with the filling compound to protect it from water-ingress.

l Accurate fiber excess length ensures good mechanical and temperature performance.

l Specially designed compact structure is good at preventing loose tubes from shrinking.

l High strength loose tube that is hydrolysis resistant and special tube filling compound ensure a citical protection of fiber.

l Moistureproof and ratproof.

 

Fiber characteristic:

Fiber style

Unit

SM G652D

MM 50/125

MM 62.5/125

MM OM3-300

Condition

nm

1310/1550

850/1300

850/1300

850/1300

Attenuation

dB/km

0.36/0.23

3.0/1.0

3.0/1.0

3.0/1.0

Dispersion

1550nm

Ps (nm ·km)

≤18

-----

-----

Dispersion

1625nm

Ps (nm ·km)

≤22

-----

-----


Bandwidth

850nm

MHZ ·.km

-----

≥400

≥160

Bandwidth

1300nm

MHZ. ·km

-----

≥800

≥500


Zero dispersion wavelength

nm

1302 ,≤1322

------

------

1295 ,≤1320

Zero dispersion slope

nm

≤0.091

------

------

≤0.11

PMD Maximum Individual Fibre

um

≤0.2

------

------

------

PMD Design Link Value

Ps/(nm2*km)

≤0.08

------

------

------

Fibre cutoff wavelength λc

nm

1180 ,≤1330

------

------

------

Cable cutoff wavelengthλcc

nm

≤1260

-------

-------

-------

Mode field diameter(MFD)

1310nm

um

9.2±0.4

------

-------

-------

1550nm

um

10.4±0.8

------

-------

-------

Numerical Aperture(NA)


-----

0.200±0.015

0.275±0.015

0.200±0.015

Step(mean of bidirectional measurement)

dB

≤0.05

≤0. 10

≤0. 10

≤0. 10

Irregularities over fibre length and point discontinuity

dB

≤0.05

≤0. 10

≤0. 10

≤0. 10

Difference backscatter coefficient

dB/km

≤0.03

≤0. 08

≤0. 10

≤0. 08

Attenuation uniformity

dB/km

≤0.01

-----

------

-----

Core diameter

um

-----

50±1.0

62.5±2.5

50±1.0

Cladding diameter

um

125.0±0.1

125.0±0.1

125.0±0.1

125.0±0.1

Cladding non-circularity

%

≤1.0

≤1.0

≤1.0

≤1.0

Coating diameter

um

242±7

242±7

242±7

242±7

Coating/cladding concentricity error

um

≤12.0

≤12.0

≤12.0

≤12.0

Coating non-circularity

%

≤6.0

≤6.0

≤6.0

≤6.0

Core/cladding concentricity error

um

≤0.6

≤1.5

≤1.5

≤1.5

Curl(radius)

um

≤4

-----

-----

-----

 

Technical Requirements:

  Fiber Count

Dia (mm)

Weight (kg/km)

Min.Bending Radius(mm)

Max Tension(N)

Crush Pressure(N/100mm)




Dynamic

Static

Short Term

Long Term

Short Term

Long Term

2-30

10.6

120

20×D

10×D

1500

600

1000

300

30-36

11.1

140

20×D

10×D

1500

600

1000

300

36-60

12.1

155

20×D

10×D

1500

600

1000

300

48-72

12.6

185

20×D

10×D

1500

600

1000

300

72-84

13.5

190

20×D

10×D

1500

600

1000

300

84-96

14.4

215

20×D

10×D

2000

600

1000

300

96-108

15.3

240

20×D

10×D

2500

600

1000

300

108-120

16.1

265

20×D

10×D

2500

600

1000

300

120-132

17.0

290

20×D

10×D

2500

600

1000

300

132-216

17.9

310

20×D

10×D

2500

600

1000

300

Previous
Next